MAJESTIC OUTDOOR GAS FIREPLACE Model: ODGSR36ANAU & ODGSR36APAU Installation and Operating Instructions Page 1 of 18
Valve Access Valve can be accessed in one of two ways: 1. Remove the front panel just below the front of the hearth pan. This is accomplished by li
Part 3: Operating Instructions Log Installation Warning: As with all plastic bags, these bags are not toys and should always be kept away from chil
Flame Adjustment For units equipped with Hi/Lo valves, flame adjustment is achieved by rotating the Hi/Lo adjustment knob located near the centre of
Page 13 of 18
Troubleshooting Nova SIT 820 Standing Pilot START CHECK Gas supply connected Gas Supply On Shut off valve open No Lockout has engag
Maintenance Burner and burner compartment It is important to keep the burner and the burner compartment clean. At least once a year the logs should
Parts List Page 16 of 18
Part 6: Warranty LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all
IF WARRANTY SERVICE IS NEEDED... 1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your
CONTENTS Part 1: For Your Safety Part 2: Installation Instructions • General Information • Fireplace Dimensions • Clearance to Combustibles •
Part 1: For Your Safety For your safety do not operate this appliance before reading this instruction book. WARNING: Improper installation, adjust
GENERAL INFORMATION FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS APPLIANCE PLEASE NOTE THE FOLLOWING: a) This appliance gives off high temperatu
Ventilation Requirements Adequate combustion and ventilation air must be provided. The flow of combustion and ventilation air MUST NOT be obstructed.
See examples below of Outdoor Areas: Figure 1: Overall and framing dimensions. Page 6 of 18
Clearance to Combustibles (Refer Figure 1) Top framing ……………………………………………………0 mm to standoff spacer Bottom……………………………………………………………0 mm Side framing
: A minimum of 100mm above the fireplace must be non-combustible material (eg fibre cement sheeting). Figure 2a Figure 2b Framing and Finishing
Figure 3 Finishing CAUTION: All joints between the finished wall and the appliance surround (top and sides) may be sealed only with a non-combustib